01 Supports three-phase unbalanced output, ensuring stable operation under complex load conditions
02 Up to 200% DC/AC oversizing to significantly boost power generation efficiency
03 Rugged IP66 enclosure design ensures performance in harsh environments
04 Enables up to 150% off-grid peak output, allowing effortless startup of inductive loads
| Model | SGA-ONE-8T-G3 | SGA-ONE-10T-G3 | SGA-ONE-12T-G3 | SGA-ONE-16T-G3 | SGA-ONE-20T-G3 |
| Battery | |||||
| Battery type | Li-ion | ||||
| Battery voltage range (V) | 720-950 | ||||
| Number of modules | 1-8(1) | ||||
| PV Input | |||||
| Recommended max. PV power (W) | 16000 | 20000 | 24000 | 32000 | 40000 |
| Max. input voltage (V) | 1000 | ||||
| Rated voltage (V) | 720 | ||||
| Start-up voltage (V) | 170 | ||||
| MPPT voltage range (V) | 150-950 | ||||
| Max. input current (A) | 20/20/20 | 20/20/20/20 | |||
| Max. short circuit current (A) | 30/30/30 | 30/30/30/30 | |||
| MPPT number/Max. input strings number | 3/3 | 4/4 | |||
| AC Output | |||||
| Rated output power (W) | 8000 | 10000 | 12000 | 16000 | 20000 |
| Max. on-grid output apparent power (VA) | 8800 | 11000(2) | 13200 | 17600 | 22000 |
| Max. output current (A) | 13.3 | 16.7 | 20 | 26.7 | 33.3 |
| Max. off-grid output apparent power (VA)(3) | 12000(10s) | 15000(10s) | 18000(10s) | 24000(10s) | 30000(10s) |
| Grid form | 3L/N/PE | ||||
| Nominal AC output voltage (V) | 380/400 | ||||
| Nominal grid frequency (Hz) | 50/60 | ||||
| Power factor | >0.99 (0.8 leading-0.8 lagging) | ||||
| THDi (@rated output) | <3% | ||||
| Efficiency | |||||
| Max. efficiency | 98.50% | ||||
| EU efficiency | 98.00% | ||||
| Protection | |||||
| Anti-islanding protection | Integrated | ||||
| PV string input reverse polarity protection | Integrated | ||||
| Insulation resistor detection | Integrated | ||||
| Residual current monitoring unit | Integrated | ||||
| AC overcurrent protection | Integrated | ||||
| AC short circuit protection | Integrated | ||||
| AC overvoltage and undervoltage protection | Integrated | ||||
| Surge protection | DC Type ll/AC Type ll | ||||
| General | |||||
| Dimensions (W × H × D [mm]) | 620 × 360 × 255 | ||||
| Weight (kg) | 31 | ||||
| Mounting | Wall-mounted / Floor-standing | ||||
| Operating temperature (℃) | -30 to +65 (>45, derating) | ||||
| Relative humidity | 0-95%, no condensation | ||||
| Cooling | Natural convection | Intelligent air cooling | |||
| Topology | Non-isolation | ||||
| Altitude (m) | ≤4000 | ||||
| Protection degree | IP66 | ||||
| Noise (dB) | <35 | <55 | |||
| User interface | LED & App | ||||
| Communication | RS485, Bluetooth, Wi-Fi / Ethernet / 4G (optional) | ||||
| Warranty | 10 Years | ||||
| Standard Compliance | |||||
| Grid connection standard | IEC 61727, IEC 62116, EN 50549-1&10, NF EN 50549-1&-10, VDE-AR-N 4105, DIN VDE V 0124-100,PN-EN 50549-1, NC RfG, CEI0-21, AS/NZS 4777.2, PEA/MEA, TOR Erzeuger Type A | ||||
| Safety / EMC standard | IEC/EN 61000-6-1, IEC/EN 61000-6-3, EN 62920, IEC/EN 62109-1&2 | ||||
| (1) Up to four modules can be stacked in one battery tower.(2) For Belgium, the maximum output apparent power is equal to the nominal output apparent power.(3) Applicable only when the inverter is connected to Hoymiles gateway. | |||||